*** Remote box calling codes ***

PK =  panic, all TA10's stop.
T0 =  TA10# 1
T1 =  TA10# 2
T2 =  TA10# 3
T3 =  TA10# 4  
T4 =  TA10# 5
T5 =  TA10# 6
T6 =  TA10# 7
T7 =  TA10# 8
T8 =  TA10# 9
T9 =  TA10# 10
T: =  TA10# 11
T; =  TA10# 12
T< =  TA10# 13
T= =  TA10# 14
T> =  TA10# 15
T? =  TA10# 16


*** TA10 response codes ***

I  =  interlock zone A
J  =  interlock zone B
V  =  interlock zone C
W  =  interlock zone D

l  = no film
L  = no film, in interlock

z  = film in
Z  = film in, in interlock

q  = start
Q  = start, in interlock

u  = show run
U  = show run, in interlock

n  = intermission
N  = intermission, in interlock

h  = failure
H  = failure, in interlock


*** ta10 asynchronous responses ***

# = ta10 ID number
& = ta10 INTERLOCK ZONE number

press start---------------- S#S#
press start in interlock----S&#S&#

stop -----------------------F#F#
stop in interlock-----------F&#F&#